Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameters:
vap inter-ap-blocking block non-ip-traffic
Result
There is no exchange of non-IP packets, for example layer 2 packets between the client and
the SCALANCE W700 devices configured on the access point as permitted communications
partners.
11.3.5.21 no vap inter-ap-blocking block non-ip-traffic
Description
This command allows the exchange of non-IP packets between the client and the SCALANCE
W700 devices that are configured on the access point as permitted communications partners.
Note
The command is only available when the following requirements are met:
Access point mode
The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5907-8PA00)
W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameters:
no vap inter-ap-blocking block non-ip-traffic
Security and authentication
11.3 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
544 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals