EasyManuals Logo

Siemens SCALANCE W770 Series User Manual

Siemens SCALANCE W770 Series
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #350 background imageLoading...
Page #350 background image
8.1.2.7 dcp server
Description
With this command, you configure the read and write permissions for the DCP server and
enable it.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
dcp server {read-only|read-write}
The parameters have the following meaning:
Parameter Description Range of values / note
read-only only reading is permitted on the DCP
server
-
read-write reading and writing is permitted on the
DPC server
Default: read-write
Result
The read and write permissions for the DPC server are configured.
The DCP server is enabled.
Further notes
You disable the DCP server with the no dcp server command.
8.1.2.8 no dcp server
Description
With this command, you disable the DCP server.
Requirement
You are in the Global configuration mode.
Network protocols
8.1 IPv4 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
350 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?