EasyManua.ls Logo

Siemens SCALANCE W770 Series

Siemens SCALANCE W770 Series
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
wlan ipcf-mc cycle-time <ms (32-512)>
The parameter has the following meaning:
Parameter Description Range of values / note
ms Cycle time in millisec‐
onds (ms)
32 ... 512
Result
The cycle time is configured.
Further notes
You display the setting with the show wlan ipcf-mc command.
5.6.2.5 wlan ipcf-mc mgmt-scan-period (client)
Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
iPCF-MC is enabled with the aid of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5 907-8PA00)
W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you the time for the background scan interval as a multiple of the update
time.
Requirement
The SCALANCE W700 device is in client mode
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc mgmt-scan-period <num-of-cycles (1-10)>
Functions specific to SCALANCE
5.6 iPCF-MC
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
144 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Related product manuals