Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
If you exit the EVENTS configuration mode with the exit command, you return to the
Global configuration mode.
If you exit the EVENTS configuration mode with the end command, you return to the
Privileged EXEC mode.
12.1.6.1 add log
Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
add log <log-entry>
The parameter has the following meaning:
Parameter Description Range of values / note
log-entry Entry in the logbook max. 150 characters
Result
The entry has been made in the logbook.
12.1.6.2 client config
Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog: sends the messages to the Syslog server
trap: sends the messages as SNMP trap to a configured recipient
email: sends the messages as e-mail
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
590 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals