EasyManuals Logo

Siemens SCALANCE W770 Series User Manual

Siemens SCALANCE W770 Series
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #556 background imageLoading...
Page #556 background image
Syntax
Call up the command with the following parameters:
ip access-list standard<access-list-number(1-20)>
The parameters have the following meaning:
Parameter Description Range of values / note
standard Specifies that a standard access control
list is generated
-
access-list-
number
Number of the standard access control
list
1 ... 20
Result
The access control list has been generated.
You are in the ACL Standard configuration mode.
The command prompt is:
cli(config-std-nacl)#
Further notes
You delete the IP access control list with the no ip access-list command.
You exit the ACL Standard configuration mode with the exit command.
You display the configuration of the access control list with the show access-lists
command.
11.5.2.2 no ip access-list
Description
With this command, you delete an IP access control list.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no ip access-list standard<access-list-number(1-20)>
Security and authentication
11.5 IP access control list
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
556 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals