The command prompt is as follows:
cli(config-mst)#
Syntax
Call the command without parameters:
no name
Result
The name is reset to the default value.
Further notes
You configure the name of the MST region with the name command.
You display this setting and other information with the show spanning tree mst
configuration command.
7.3.5.5 revision
Description
With this command, you assign a revision number to the MST region.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call up the command with the following parameters:
revision <revision-no(0-65535)>
The parameters have the following meaning:
Parameter Description Range of values / note
revision-no Value of the revision number 0 ... 65535
Default: 0
Result
The MST region is assigned a revision number.
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
338 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals