Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
no smtp-port
Result
The SMTP port is reset to the default value.
Further notes
You configure the setting with the smtp-port command.
You display the setting with the show smtp-port command.
8.8 HTTP server
This section describes commands of the Hypertext Transfer Protocol (HTTP).
8.8.1 The "show" commands
This section describes commands with which you display various settings.
8.8.1.1 show ip http server status
Description
This command shows the status of the HTTP server.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Network protocols
8.8 HTTP server
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface