8.1.3.4 dcp forwarding
Description
With this command, you configure the forwarding behavior of the interface for DCP frames.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
dcp forwarding {block|forward}
The parameters have the following meaning:
Parameter Description
block DCP frames are discarded
forward DCP frames are forwarded
Default: forward
Result
The forwarding behavior of the interface for DCP frames is configured.
8.2 IPv6 protocol
This section describes the commands relevant for working with IPv6.
8.2.1 Configuration matrix
Address configuration in
WBM
(System > Agent IPv6)
CLI commands
ipv6 address autocon‐
fig
ipv6 address dhcp ipv6 address
Automatic x x -
DHCPv6 - x -
SLAAC x - -
Static - - x
Network protocols
8.2 IPv6 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
358 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals