EasyManuals Logo

Siemens SCALANCE W770 Series User Manual

Siemens SCALANCE W770 Series
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Result
The latitude coordinate is created.
4.1.10.3 coordinates longitude
Description
With this command, you enter a longitude coordinate.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
coordinates longitude <longitude>
The parameter has the following meaning:
Parameter Description Range of values / note
longitude Input box for the longitude coordinate max. 32 characters
To use spaces in the entry, enter
the longitude coordinate in quotes:
coordinates longitude
"123 456"
Result
The longitude coordinate is created.
4.1.10.4 ethernetip
Description
With this command, you set whether EtherNet/IP will be enabled or disabled after the next
device restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
Configuration
4.1 System
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 67

Table of Contents

Questions and Answers: