Syntax
Call up the command with the following parameters:
username {admin} password <passwd>
The parameters have the following meaning:
Parameter Description Range of values / note
admin User name of the default user with
read and write access to the config‐
uration data.
-
password Keyword for a password -
passwd Value for the password Enter the password.
The strength of the password depends on
the set password policy:
low: Password length: at least 6
characters
high: The password must meet the
following conditions:
Password length: at least 8
characters
at least 1 uppercase letter
at least 1 special character
at least 1 number
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
Further notes
You show the created users with the show user-accounts command.
You can also change the passwords with the user-account command.
You display the currently valid password policy with the show password-policy command.
11.1.4.10 password policy
Description
With this command you specify which password policy will be used when assigning new
passwords.
Security and authentication
11.1 User rights management
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
486 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals