10.1.3.4 no nat (Client)
Note
This command is only available in the client mode.
Description
With this command, you delete an entry from the translation list.
Note
This command is only available in the client mode
Requirement
You are now in the NAT Configuration mode.
The command prompt is as follows:
cli(config-nat)#
Syntax
Call up the command with the following parameters:
no nat {tcp|udp} <globalportfrom> [<globalportto>] <localip>
<localportfrom> [<localportto>]
The parameters have the following meaning:
Parameter Description Range of values / note
tcp Assignment of TCP for the follow‐
ing global port
-
udp Assignment of UDP for the follow‐
ing global port
-
globalportfrom Start port of the global port range enter the start port
globalportto End port of the global port range enter the end port
localip IPv4 address of the node in the lo‐
cal network
enter a valid IPv4 address
localportfrom Start port of the local port range enter the start port
localportto End port of the local port range enter the end port
Result
The entry is deleted from the translation list.
Layer 3 functions
10.1 NAT
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 461

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals