nat {tcp|udp} <globalportfrom> [<globalportto>] <localip>
<localportfrom> [<localportto>] [{enable|disable}]
The parameters have the following meaning:
Parameter Description Range of values / note
tcp Assignment of TCP for the follow‐
ing global port
-
udp Assignment of UDP for the follow‐
ing global port
-
globalportfrom Start port of the global port range enter the start port
globalportto End port of the global port range enter the end port
localip IPV4 address of the node in the lo‐
cal network
enter a valid IPv4 address
localportfrom Start port of the local port range enter the start port
localportto End port of the local port range enter the end port
enable Enables the NAT rule -
disable Disables the NAT rule -
Note
Global port
If the port is already occupied by a local service, for example Telnet, a warning is displayed.
In this case, avoid using TCP port 23 (Telnet), port 22 (SSH), ports 80/443 (http/https:
reachability of the client with the WBM) and UDP port 161 (SNMP) as global port.
Result
The translation list is configured.
If the command is executed without the optional parameters enable|disable, the newly
created address assignment is disabled as default.
Further notes
You show the NAT configuration and the translation list with the show nat command.
You delete entries with the no nat command.
See also
show nat (Client) (Page 456)
Layer 3 functions
10.1 NAT
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
460 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals