Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
user-group <user-group-name> role <role-name> [description <user-
group-description>]
The parameters have the following meaning:
Parameter Description Range of values / note
user-group Keyword for a group name -
user-group-name Group name Enter the name of the group. The name
must match the group on the RADIUS
server.
The name must meet the following condi‐
tions:
It must be unique.
It must be between 1 and 64
characters long.
role Keyword for the role name -
role-name Role name Enter a role name. Users who are author‐
ized with the linked group on the RADIUS
server receive the rights of this role locally
on the device.
You can choose between system-defined
and self-defined roles.
description Keyword for the description -
user-group-
description
Content of the description Enter a description for the link. The de‐
scription text can be up to 100 characters
long.
Result
The group is linked to a role.
Further notes
You delete a link with the no user-group command.
You show the created links with the show user-groups command.
Security and authentication
11.1 User rights management
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
484 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals