Configurable function Maximum number
Security IP addresses from RADIUS servers
AAA: 4
WLAN: 2
Management ACLs (access rules for management) 10
MAC ACL rule configuration 20
Ingress and egress rules for MAC ACL (total) 40 per interface (20 ingress rules /
20 egress rules)
Client: 80 (P1, WLAN)
Access point: 680 (P1, WDS
1.Y, VAP 1.Y)
IP ACL rule configuration 20
Ingress and egress rules for port ACL IP (total) 40 per interface (20 ingress rules /
20 egress rules)
Client: 120 (P1, WLAN,
management VLAN)
Access point: 720 (P1, WDS
1.Y, VAP 1.Y, management
VLAN)
User roles 28
User groups 32
Users 28
Support of IPv6
The following system functions do not support IPv6 addresses:
Inter AP blocking
Force roaming
IP ACL
Management ACL
Note
Interruption of the WLAN communication
The WLAN communication can be influenced by high frequency interference signals and can
be totally interrupted.
Remember this and take suitable action.
Description
2.1 Configuration limits for WBM and CLI
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
24 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals