Syntax
Call up the command with the following parameters:
wlan mode { show-modes | [2.4 | 5] <mode>}
The parameter has the following meaning:
Parameters Description Range of values / note
show-
modes
Lists the transmission standards. --
2.4 Optional. You can use the param‐
eter in conjunction with "auto"
and "n". This only takes into ac‐
count the transmission stand‐
ards for 2.4 GHz.
Use the parameter if the client
operates in dual-frequency
mode.
--
5 Optional. You can use the param‐
eter in conjunction with "auto"
and "n". This only takes into ac‐
count the transmission stand‐
ards for 5 GHz.
Use the parameter if the client
operates in dual-frequency
mode.
--
mode Value corresponding to a specific
transmission standard.
auto
The transmission standard is detected
automatically.
a
IEEE 802.11a (5 GHz)
g
IEEE 802.11g (2.4 GHz)
Is downwards compatible with IEEE 802.11b
n
IEEE 802.11n (2.4 GHz + 5 GHz)
Is downwards compatible with IEEE 802.11a and
IEEE 802.11g
n-only
IEEE 802.11n (2.4 GHz + 5 GHz)
Is not downwards compatible with IEEE 802.11a
and IEEE 802.11g
Depending on the current configuration, some settings are not possible. In this case, a
message to this effect is displayed.
Result
The transmission standard is specified.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 257

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals