[timeout <Seconds(1-1500)] [retries <RetryCount(1-3)]
[taglist <TagIdentifier | none>] [{volatile | nonvolatile}]
[port <integer (1-65535)>]
The parameters have the following meaning:
Parameter Description Range of values / note
TargetAddressName Name of the target address Maximum of 32 characters
param Keyword for the parameter name -
ParamName Name of the parameter Maximum of 32 characters
ipv4 Keyword for an IPv4 address -
IPAddress IPv4 address of the trap recipient: Enter a valid IPv4 unicast address.
fqdn-name Keyword for a domain name -
FQDN Domain name (Fully Qualified Do‐
main Name) of the trap recipient
Maximum of 100 characters
If you have stored a suitable domain
name, you can specify a host name.
ipv6 Keyword for an IPv6 address -
IP6-Address IPv6 address of the trap recipient Enter a valid IPv6 address.
timeout Keyword for the time the SNMP agent
waits for a response before it repeats
the inform request message
-
Seconds Time in seconds 1 ... 1500
retries Keyword for the maximum number of
attempts to obtain a response to an
inform request message
-
RetryCount Number of attempts 1 ... 3
taglist Keyword for tag list -
TagIdentifier Tag identifier that selects the destina‐
tion address for SNMP.
Specify the tag identifier.
none No tag identifier -
volatile
nonvolatile
Specifies whether the settings re‐
main following a restart.
volatile:
The default settings are used
after a restart.
nonvolatile:
The saved settings are used after
a restart.
port Keyword for the port number at which
the SNMP manager receives traps
and inform messages
-
integer Port number 1 ... 65535
For information on addresses and interfaces, refer to the section "Addresses and interface
names".
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target address is configured.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 427

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals