Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3 {auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
ParamName Name of the SNMP parameter max. 32 characters
user Keyword for the user name -
UserName Value for the user name max. 32 characters
security-model Specifies which SNMP version is used.
With SNMPv3 a security level (authen‐
tication, encryption) can also be config‐
ured.
SNMP version
v1
v2c
v3
Security level for v3
auth
Authentication enabled / no
encryption enabled
noauth
No authentication enabled,
no encryption enabled
priv
Authentication enabled /
encryption enabled
message-
processing
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
SNMP version
v1
v2c
v3
Settings after the restart
:
The settings are lost after a
restart
:
The settings are retained
after a restart
Keywords need to be specified.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 429

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals