E1 Configuration
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
263
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
CONFIGURE OPTIONAL PARAMETERS FOR E1 CONTROLLER
TO CONFIGURE FRAMING
The service provider determines which framing type, either crc4 or no-crc4 is
required for your E1 circuit.
E
XAMPLE
The following example sets the E1 frame type to no crc4:
ALU(config-controller E1)#framing no-crc4
The following example sets the E1 frame type to crc4:
ALU(config-controller E1)# no framing
T
O CONFIGURE LINE-TERMINATION
E
XAMPLE
The following example selects 120 as the E1 line impedance:
ALU(config-controller E1)#line-termination 120
Command (in CCM) Description
framing {crc4|no-crc4} Use this command to configure framing
to either crc4 or no-crc4.
no framing The “no” command sets the framing to
its default.
The default framing value is crc4 in
case of E1.
Command (in CCM) Description
line-termination
{75ohm|120ohm}
Use this command to configure a line
impedance of 75 or 120 ohm.
no line-termination The “no” command sets the impedance
value to its default.
The default line-termination value is
120 ohm.

Table of Contents

Other manuals for Alcatel-Lucent OmniAccess 5740

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniAccess 5740 and is the answer not in the manual?

Alcatel-Lucent OmniAccess 5740 Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniAccess 5740
CategoryGateway
LanguageEnglish

Related product manuals