O INITIATE ETHERNET OAM FAULT VERIFICATION TEST - LOOPBACK TEST
Loopback test is initiated for fault verification (Example: Ping)
E
XAMPLE
ALU(config-oam)# eth-cfm loopback 1111.1111.1111 mep 10 domain
1 association 10 datasize 100
T
O INITIATE ETHERNET OAM FAULT ISOLATION TEST - LINK TRACE TEST
Linktrace test is used for fault isolation (Example: Trace route).
E
XAMPLE
ALU(config-oam)# eth-cfm linktrace 1111.1111.1111 mep 10 domain
1 association 10 ttl 10
Command (in OAM CM) Description
eth-cfm loopback <mac-address>
mep <1-8191> domain <0-65535>
association <0-65535>
[{datasize <1-255>|priority
<0-7>|send-count <1-5>}]
This command is used to initiate a
loopback test.
Command (in OAM CM) Description
eth-cfm linktrace <mac-
address> mep <1-8191> domain
<0-65535> association <0-
65535> [ttl <1-255>]