• Stops at the rear end of the layer of tape on the outer jacket at the other end of the splice
• Makes a 50 percent overlap.
(15) Tightly wind a second layer of the tape on the splice assembly.
Make sure that the layer of tape:
• Starts 1 inch minimum farther than where the first layer of tape stops
• Stops 1 inch minimum farther than where the first layer of tape starts
• Makes a 50 percent overlap.
(16) Assemble a lacing tape wire harness tie on each end of the splice assembly approximately 0.25
inch from the end of the tape. Refer to Subject 20-10-11.
Make sure that the Temperature Grade of the lacing tape is Temperature Grade D.
ASSEMBLY OF SPLICES
707, 727-787
STANDARD WIRING PRACTICES MANUAL
20-30-12
Page 221
Jun 15/2021D6-54446
ECCN 9E991 BOEING PROPRIETARY - See title page for details