E. Closed End Splice Configurations - Unsealed Closed End Splice - Parallel Splice, Sleeve
NOTE: A satisfactory alternative for an unsealed closed end splice is a sealed closed end splice.
Refer to Paragraph 5.B. or Paragraph 5.C.
(1) Make a selection of an uninsulated parallel splice from Table 8.
Make sure that the splice has the smallest CAU range that can accept the total CAU of the
conductors. Refer to Paragraph 1.D. for the procedure to calculate the CAU of the conductors.
(2) Find the crimp barrel size of the splice from Table 8.
(3) Make a selection of a crimp tool from:
• Table 38 for AMP 3413() parallel splices
• Table 39 for Raychem D-609-0() parallel splices.
(4) Remove the necessary length of insulation from the end of each wire.
Refer to:
• Figure 19
• Table 61 for the insulation removal length
• Subject 20-00-15 for the insulation removal procedures.
CONFIGURATION OF THE CLOSED END SPLICES
Figure 18
ASSEMBLY OF SPLICES
707, 727-787
STANDARD WIRING PRACTICES MANUAL
20-30-12
Page 63
Feb 15/2021D6-54446
ECCN 9E991 BOEING PROPRIETARY - See title page for details