Table 124 CABLE TRIM DIMENSIONS (Continued)
Cable Conductor
Trim Dimension
(inch)
Dimension Target Tolerance
F
C1
D1 0.28
±0.02D2 0.77
D3 1.05
C2
D1 0.28
±0.02D2 1.92
D3 2.20
L. Sealed Splice Configurations for Shielded Wire and Cable - Solder Shield Splice Kit - One Class
3 Shielded Cable to Three Shielded Wires
Table 125
SPLICE KITS FOR ONE CLASS 3 SHIELDED CABLE TO THREE SHIELDED WIRES
Jacket Maximum
O.D.
Shield Minimum
O.D.
Conductor CAU Range Solder Shield Splice Kit
Minimum Maximum Part Number Supplier
0.18 0.10 3 15 D-150-0179 Tyco/Raychem
0.22 0.14 8 27 D-150-0180 Tyco/Raychem
0.34 0.19 19 67 D-150-0181 Tyco/Raychem
ONE CLASS 3 SHIELDED CABLE TO THREE SHIELDED WIRES
Figure 286
ASSEMBLY OF SPLICES
707, 727-787
STANDARD WIRING PRACTICES MANUAL
20-30-12
Page 315
Jun 15/2021D6-54446
ECCN 9E991 BOEING PROPRIETARY - See title page for details