EasyManuals Logo

Dell PowerConnect 5424 Command Line Interface Guide

Dell PowerConnect 5424
512 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #350 background imageLoading...
Page #350 background image
350 Spanning-Tree Commands
spanning-tree max-age
The spanning-tree max-age Global Configuration mode command configures the spanning-tree bridge
maximum age. Use the no form of this command to reset the default maximum age.
Syntax
spanning-tree max-age
seconds
no spanning-tree max-age
seconds
-Time in seconds. (Range: 6 - 40)
Default Configuration
The default max-age for IEEE STP is 20 seconds.
Command Modes .
Global Configuration mode
User Guidelines
When configuring the Max-Age the following relationships should be kept:
2*(Forward-Time - 1) >= Max-Age
Max-Age >= 2*(Hello-Time + 1)
Example
The following example configures the spanning-tree bridge maximum-age to 10 seconds.
spanning-tree priority
The spanning-tree priority Global Configuration mode command configures the spanning-tree priority.
The priority value is used to determine which bridge is elected as the root bridge. Use the no form of this
command to reset the default spanning-tree priorit.
Syntax
spanning-tree priority
priority
no spanning-tree priority
priority
— Priority of the bridge. (Range: 0 - 65535 in steps of 4096)
Default Configuration
The default bridge priority for IEEE STP is 32768.
Console(config)# spanning-tree max-age 10
5400_CLI.book Page 350 Wednesday, December 17, 2008 4:33 PM

Table of Contents

Other manuals for Dell PowerConnect 5424

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5424 and is the answer not in the manual?

Dell PowerConnect 5424 Specifications

General IconGeneral
Ports24 x 10/100/1000Base-T
Switching Capacity48 Gbps
Forwarding Rate35.7 Mpps
VLAN SupportYes
Rack MountableYes
Power SupplyInternal
MAC Address Table Size8K entries
RAM128 MB
Flash Memory16 MB
Voltage Required100-240V AC
ManagementWeb, CLI, SNMP
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% (non-condensing)
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Remote Management ProtocolSNMP, RMON, Telnet
FeaturesQoS, VLAN, Link Aggregation

Related product manuals