RMON Commands 323
The following table describes the significant fields shown in the display:
show rmon log
The show rmon log User EXEC mode command displays the RMON logging table.
Syntax
show rmon log
[
event
]
event
— Event index. (Range: 0 - 65535)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode.
User Guidelines
There are no user guidelines for this command.
Field Description
Index An index that uniquely identifies the event.
Description A comment describing this event.
Type The type of notification that the device generates about this event. Can have the
following values: none, log, trap, log-trap. In the case of log, an entry is made in the
log table for each event. In the case of trap, an SNMP trap is sent to one or more
management stations.
Community If an SNMP trap is to be sent, it is sent to the SNMP community specified by this
octet string.
Owner The entity that configured this event.
Last time sent The time this entry last generated an event. If this entry has not generated any
events, this value is zero.