Inspection Mode
3-26 Manual # 42-02-7223
Running on Machine Room Inspection
When you are ready to run the elevator on Inspection:
1. Verify the iBox Computer, Safety A, Safety B, and Cartop status LEDs are lighted solidly
green.
2. Move the Inspection switch to the INSP position.
3. Move the Controller Stop switch to the RUN position.
Within 5 seconds, Safety OK and Doors Locked LEDs should be on and the Fault LED should be off.
4. Verify that Car Door Bypass and Hall Door Bypass iBox switches are set to the OFF posi-
tion.
5. Verify that the car is in Machine Room Inspection on the iBox or in iView. If the car is in
another inspection mode (i.e., Cartop Inspection, In-car Inspection, or Hoistway
Access), turn them off. The INCT, INA, and INCP inputs on the left edge of the iBox
should be high (110VDC).
6. Press and hold the iBox Enable button, then press the Up or Down button to run the car
on inspection. Run the car away from the terminal landing.
7. On the iBox or on the iView Hoistway screen, verify car speed (Actual Speed). Calibrate
if required. Please refer to “Verifying Motor Rotation and Control (Quattro DC Drive)”
on page 2-81.