Page #666 background image
iView - System View
10-6 Manual # 42-02-7223
System Configuration tab
The System Configuration tab is used to program the dispatching parameters for a Simplex car,
Swing car, or AGC (Local Dispatcher). This tab provides access to controls affecting dispatch-
ing, parking, operational modes, etc.
Through the tree on the left side of this tab, you can access:
•Building: Set the highest floor served, number of cars, floor and
car labels, etc. (see page 10-7).
•CFSS: Set recall-to-floor eligibility when operating in a Com-
mandeer for Special Service mode (see page 10-9).
•Dispatching: General dispatching controls (see page 10-11).
•Hall Call Eligibility: On a per-floor, per-configuration basis (1
— 8), select the hall calls to which the car(s) may respond (see
page 10-14).
•Mode of Operation: Setup the dispatching mode of operation
parameters and configurations (see page 10-15).
•Parking: Set parking options and floors for Parking configura-
tions (see page 10-21).
•Parking Eligibility: On per-configuration basis (1 — 8), set the
parking eligibility parameters for the car (see page 10-28).
•Split Bank: Split Bank operation is available only on the Cen-
tral Dispatcher (see page 10-30).
•Management: Provides access to the following:
•Remote Monitoring Authorization: Use to authorize a third
party remote monitoring tool to connect to iControl (see
page 10-32).
•Local Dispatcher: Use to force the system to resend the sys-
tem parameters to all connected cars (see page 10-33).
•Destination Based Dispatching: Use to enable DBD and set
general DBD parameters (see page 10-34).
•Kiosk Configuration: Set destination input device (Kiosk)
parameters (see page 10-36).
•Hallway Configuration: Set walk time, car capacity and
accessibility parameters (see page 10-37).
•Special operations configuration: Parameters used to control
special operations (see page 10-38).