iView - Controller View
9-116 Manual # 42-02-7223
Configuration - Floor Heights
The Configuration > Floor Heights > Configurations tab is used to view the learned values for
the floor heights.
Level Up Top: The learned distance from the bottom floor to the top of the floor magnet as
determined by the Level Up sensor.
Level Up Bottom: The learned distance from the bottom floor to the bottom of the floor
magnet as determined by the Level Up sensor.
Level Down Top: The learned distance from the bottom floor to the top of the floor magnet
determined by the Level Down sensor.
Level Down Bottom: The learned distance from the bottom floor to the bottom of the floor
magnet determined by the Level Down sensor.
Floor Offsets Tab
Offsets: The variance from the floor magnet position to the
actual floor level position. The offset value is determined by
performing the floor offset calibration procedure (Setup >
Floor Heights > Floor Offsets). Please refer to “Calibrating
the Floor Offsets” on page 4-28.