iView - Controller View
9-54 Manual # 42-02-7223
Fire Code - Recall - Front / Rear Door Tabs
Determine how the doors shall open and close during Fire Recall operation.
Recall Not Completed - Recall Completed Determine how the doors shall open
and close before recall has been completed and after recall has been completed. The parameters
and descriptions are the same for both Recall Not Completed and Recall Completed and for
both Front and Rear tabs.
Opening When “MCE Controlled” is checked, the following parameters determine what
action will cause the doors to open when the car arrives at a floor.
Mechanism:
Automatic: With the presence of door open intent, doors shall open automatically upon
arrival at the floor. When the car is sitting idle, the doors will open and remain open.
Constant pressure on door open button: Doors shall not open automatically upon arrival
at a floor. Constant pressure activation of the door open button is required to open the
doors. If the door open button is released before the doors are fully open, the doors shall
re-close.
Momentary pressure on door open button: Doors shall not open automatically upon
arrival at a floor. Momentary activation of the door open button shall initiate opening the
doors.