iView - System View
10-54 Manual # 42-02-7223
COP buttons: Calls placed using COP buttons while the car is operating in one of the
following modes: Attendant Service, CFSS 1, CFSS2, Independent service, Test mode,
Shuttle service.
5. Click OK.
Active overrides are displayed as single letters, each corresponding to a mode:
I = Independent A=Attendant 1=CFSS1 2=CFSS2 D=Auto Door
T=Test Mode E=Emerg Dispatch S=Sabbath R=Remote O=OBD
Car Calls - Passcodes
This screen allows you to set parameters that pertain to per-floor and passenger passcodes.
Timeout between buttons: Passcodes are entered using car operating panel (COP) buttons.
When the passenger is entering a passcode, if more than the number of seconds set here
elapses between button presses, the passcode entry will time out.
Passenger passcode length: Sets the length of the passenger passcodes. (It is recom-
mended that the passenger passcode length and floor passcode length be the same).
Car Calls - Passcodes - Floor
This tab allows you to assign per-floor car call enable passcodes (passcodes are entered using
COP buttons). To program a floor passcode
1. Select the Configuration (1 - 8).