EasyManuals Logo

MCE iControl User Manual

Default Icon
806 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #596 background imageLoading...
Page #596 background image
iView - Controller View
9-118 Manual # 42-02-7223
General - Floor Data Tab
Floor data settings provide information about floor openings, floor labels, and door boost.
Note
Rather than proceeding floor-by-floor, column-by-column, you may choose to select a column
head or multiple cells and use the “system wide” Select/Deselect controls to set all floors the
same for that topic (where appropriate). You can also move from field to field using the Tab key.
Floor Data Settings For each floor:
Floor: This is the floor number.
Floor label: Since each car can have different express zones and floor labels, the floor
labels must be set on each individual car and also on the iCentral or Local Dispatcher (Sys-
tem > Configuration > Building tab). Please refer to “Building” on page 10-7.
False Floor: Indicate whether or not this is a false floor (no openings).
Front/Rear Opening: Indicate whether the car has front and/or rear opening doors. A
check mark indicates the opening is available.
Door Boost Front/Rear: Enable/Disable Door Boost to compensate for heavy doors or
wind loading at a particular location.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MCE iControl and is the answer not in the manual?

MCE iControl Specifications

General IconGeneral
BrandMCE
ModeliControl
CategoryController
LanguageEnglish