Configuration - I/O Boards
9-137
9
iControl DC
•Fire Detectors
Fire Detectors Floor (1 - 96): Signals that a fire detector on floor (1 - 96) is activated.
User Serial Fixtures Messages
User Serial Fixture Message (1 - 4): Activation causes a user defined message to be dis-
played and/or announced on the serial fixtures (See “Serial Fixtures” on page 9-38.).
•Jail Operation
Jail Master Mode Input: Activation places the car in Jail Master Mode operation.
Jail Secure Mode Input: Activation places the car in Jail Secure Mode operation.
Jail Mode Override Input: Activation overrides Jail Mode.
Output Signal Groups
Outputs are logic-enabled and provide current/voltage or a path to ground as determined by
the common shared by the particular relay group. Refer to your job prints for active signal level
and specific connection information. The following output groups can be programmed on the
ICE-MOR or ICE-COP boards.
•Elevator
Alarm Buzzer: Activated if the Emergency Stop Switch or Alarm Bell input are acti-
vated and will pulsate if the SAFH, SAFC or GOV inputs go low or if the TDISL input is
used. It is reset using the “Emergency Alarm Reset input”. Configure using the Config-
uration > Car Operation > Devices tab (Emergency Alarm Monitoring parameters).
Alarm Light: Activated due to an extended safety string fault, emergency stop switch or
alarm bell activation. It is reset using the “Emergency Alarm Reset input”. Configure
using the Configuration > Car Operation > Devices tab (Emergency Alarm Monitoring
parameters).
Attendant Buzzer: This output turns on momentarily (activates an in-car buzzer) to
indicate that a hall call button has been pressed while the elevator is on attendant
operation.
Attendant Hall Call Above: While on attendant operation, this output comes on to
indicate that the car has been assigned to answer a hall call above the car (normally
used to activate an indicator light to alert the attendant).
Attendant Hall Call Below: While on attendant operation, this output comes on to indi-
cate that the car has been assigned to answer a hall call below the car (normally used to
activate an indicator light to alert the attendant).
Attendant Service Indicator: Active when the car is on Attendant service.
Available for fire service: Active when the car is available for fire service operation.
Backup power recall done: The car is at a floor and the required door operations have
been completed.
Car Call Audible: Active momentarily when a call is entered. Used for certain CSA
applications that require ‘barrier free’ operation.
Car Call Enable 1 (2) Override output: These respective outputs are active when the
Car Call Enable 1 (or 2) Override is active.
Car Call Registered Audible: This output comes on momentarily when a car call is reg-
istered. It is used for certain CSA applications that require “barrier free” operation.