Final Adjustment
4-4 Manual # 42-02-7223
If the Car Does Not Stop and Correct Properly
•Check the iBox status display. Verify:
ULM, DLM, and DZ signals are working properly
Safety OK = ON - safety string is made up.
Doors Locked= ON - all doors are locked.
Inspection = OFF - not on Inspection operation.
Fault = OFF - no faults are active.
Initiating a One Floor Run
Note
Because we have not yet learned the speeds and positions of the Normal and Emergency Termi-
nal Limit switches, stay away from the terminals to avoid tripping faults. Remember that Fault
Bypasses are on a 15-minute time limit. If you need more time, set Fault Bypass quickly to OFF,
then back to ON (within two seconds).
The car should now be at a floor. Avoid running the car close to a terminal landing. To initiate a
one-floor run:
1. Register a car call one floor above or below the current
car position:
Click the Car Call Registration button .
Select Car Calls, then Front or Rear panel.
Click a floor selection button.
If Initiation is not Successful
If the car does not move, check the iBox status display. Verify:
Safety OK = ON - safety string is made up.
Doors Locked = ON - all doors are locked.
Inspection = OFF - the car is not on Inspection operation.
Faults = OFF - there are no active faults.