iView - System View
10-46 Manual # 42-02-7223
General
The Security Level is set on the System > Configuration > Security > General screen.
The following Security Level options are available:
• No Security: Security is not being used.
• Basic Security with per floor codes:
• Basic Security with per floor and passenger codes.
• Remote Security (card reader).
General - Configuration
This tab allows you to set the active security configuration manually or by timed assignment
and to Enable Hardware Override.
To set the security configuration manually
1. Select Manual in Configuration Assignment.
2. Set the desired configuration in the drop-down list.
3. Click Send.
To have the active security configuration set by timer table
1. Select Timed in Configuration Assignment.
2. Click Send.
3. Program one or more timer tables (System > Configuration > Timer tables tab).
Enable Hardware Override: The Security override - Master security override input is ignored
unless this control is activated.