iView - Controller View
9-80 Manual # 42-02-7223
Cancel car calls if doors are not fully closed: If enabled, during in-car CFSS operation, if
the doors are not fully closed, new car calls may not be registered and existing car calls will
be canceled.
Retain status during power loss: If enabled, the car will retain its in-car CFSS status after
recovering from a power loss.
CFSS Mode ‘n’ - Front / Rear Tabs The CFSS Mode 1 and 2 > Front and Rear tabs
determine how the front and rear doors will operate during CFSS operation. The parameters
and descriptions are the same as those for EMS Switch 1 and 2 > Front and Rear tabs. Please
refer to “EMS Switch ‘n’ - Front / Rear Tabs” on page 9-71
Car Operation - Flood Operation Tab
This tab allows the elevator to be configured for emergency operation during flood conditions.
Enable In areas where flood operation is not required, this option may be left unchecked.
If enabled, the flood condition selections on the screen become active.
Flood Floors During flood operation, floors in danger of flooding shall be avoided. The
topography and construction at each job site will determine which and how many floors are
affected.
Click in the Flood floors column, the floors that should not be serviced during flood opera-
tion. A check mark will appear next to each selected floor.