EasyManuals Logo

MCE iControl User Manual

Default Icon
806 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #529 background imageLoading...
Page #529 background image
Configuration - Car Operation
9-51
9
iControl DC
Fire Code - Recall - General Tab
This tab allows you to set various fire code recall parameters.
Latch primary fire recall switch:
Never: The recall condition will clear automatically when the initiating condition
clears.
Fire device OFF: In order to clear the recall condition, the primary fire recall switch
must be off.
Primary bypass: In order to clear the recall condition, the primary fire recall switch
must be turned to the BYPASS position.
Bypass and recall completed: In order to clear the recall condition, the car must be at
the fire floor with doors open and the primary fire recall switch must be turned to the
BYPASS position.
Recall completed all cars: In order to clear the recall condition, the fire recall must be
completed for all elevators in the group.
Primary bypass then OFF: In order to clear the recall condition, the primary fire switch
must be turned to the BYPASS position and then back to off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MCE iControl and is the answer not in the manual?

MCE iControl Specifications

General IconGeneral
BrandMCE
ModeliControl
CategoryController
LanguageEnglish