Fire Code - Recall - General Tab
This tab allows you to set various fire code recall parameters.
Latch primary fire recall switch:
Never: The recall condition will clear automatically when the initiating condition
clears.
Fire device OFF: In order to clear the recall condition, the primary fire recall switch
must be off.
Primary bypass: In order to clear the recall condition, the primary fire recall switch
must be turned to the BYPASS position.
Bypass and recall completed: In order to clear the recall condition, the car must be at
the fire floor with doors open and the primary fire recall switch must be turned to the
BYPASS position.
Recall completed all cars: In order to clear the recall condition, the fire recall must be
completed for all elevators in the group.
Primary bypass then OFF: In order to clear the recall condition, the primary fire switch
must be turned to the BYPASS position and then back to off.