iControl Circuit Board Quick References
6-83
6
iControl DC
Figure 6.2 ICE-COP-2 Serial Car Operating Panel Board
Test points,+5v
Reset button
OUT to additional
ICE-COP boards
(RJ45)
I/O
connections
24 VDC
6W max.
To CTP board in
iLink Cartop box
8-position DIP
switch package
+24VDC power
for COP
buttons
4-pin “universal” inputs may be used
instead of screw terminals if desired.
NOT USED for
iControl
IN from additional
ICE-COP boards
(RJ45)
I/O Status LEDs
SPA processor OK
Test point,+3.3v
Test point COM, GND
Board power
input. See
prints.
Caution
This system is designed for 24 VDC circuits
maximum. Connecting 120VAC or DC will
open the input fuses.
COM
+24V
CAR CALL
BUTTON
+24V SIGNAL
COM
Connection Example:
Universal 4-pin inputs