Configuration - Car Operation
9-45
9
iControl DC
Door Dwell Timers These timers set the door dwell times.
Reopen: The amount of time that the doors are to remain open (dwell) when a door
reopening device or open button has been activated.
Door hold: The amount of time that the doors are to remain open when reopened by the
activation of the Door Hold button.
ADA car call: The minimum amount of time that the doors are to remain open after arriv-
ing at a floor selected by a car call per ADA requirements. Door dwell is not shortened by
activation of a button or door reopening device (call or door close button, etc.). Timer
starts when doors are fully open.
ADA hall call: The minimum notification time from activation of the hall gong to when the
door is about to close as required by the Americans with Disabilities Act. This dwell is not
shortened by activation of a car call or door close button.
•Car Call
Dwell time: The amount of time that the doors are to remain open when responding to
a car call. Any of the following may be specified to cancel car call dwell time:
Door close button: Pressing the door close button will cancel car call dwell time.
Car call button: Pressing a car call button will cancel car call dwell time.
Photo eye: Activation of the photo eye detector will cancel car call dwell time.
Hall Call
Dwell time: The amount of time that the doors are to remain open when responding to
a hall call. Any of the following may be specified to cancel hall call dwell time.
Door close button: Pressing the door close button will cancel hall call dwell time.
Car call button: Pressing a car call button will cancel hall call dwell time.
Photo eye: Activation of the photo eye detector will cancel hall call dwell time.
•Lobby Call
Dwell time: The amount of time that the doors are to remain open when responding to
a call at the lobby floor. Any of the following may be specified to cancel lobby call dwell
time:
Door close button: Pressing the door close button will cancel lobby call dwell time.
Car call button: Pressing a car call button will cancel lobby call dwell time.
Photo eye: Activation of the photo eye detector will cancel lobby call dwell time.