iView - Controller View
9-66 Manual # 42-02-7223
• Car call disposition: Determines how existing car calls are handled when the Elevator
Recall Switch is activated.
• Service existing car calls: All previously registered car calls remain registered and the
elevator is allowed to answer the car calls.
• Cancel immediately: All previously registered car calls are immediately canceled.
• Cancel at the next car call stop: All previously registered car calls remain registered.
When the elevator answers its next car call, all remaining car calls are canceled.
• Allow new car call registration: Determines if new car calls shall be registered during the
“first phase” of elevator Recall Operation. During the “first phase” of Elevator Recall Oper-
ation, the elevator must handle existing car calls. This parameter determines if new car
calls shall be registered during the “first phase” of Elevator Recall Operation. Once the ele-
vator has finished answering all registered car calls, the “second phase” commences, and
the elevator is taken to the recall floor. No car calls are accepted during the “second
phase.”
• Override Attendant service: Elevator Recall operation shall override Attendant service.
• Override CFSS mode 1: Elevator Recall operation shall override CFSS mode 1.
• Override CFSS mode 2: Elevator Recall operation shall override CFSS mode 2.
• Override EMS mode 1: Elevator Recall operation shall override EMS mode 1.
• Override EMS mode 2: Elevator Recall operation shall override EMS mode 2.
• Override Independent service: Elevator Recall operation overrides Independent service.
• Switch type: Indicates the type of Elevator Recall Switch.
• Continuous closure: The controller performs the Elevator Recall Operation as long as
the switch remains closed. If the switch opens midway through the process, the recall
operation is terminated.
• Momentary closure: A momentary closure of the switch causes the controller to per-
form the complete Elevator Recall Operation. Once completed, the controller will
return to normal service.
• Resume normal operation after ___ sec: This timer begins when door operation at
the recall floor is complete. When the timer expires, the car is returned to normal
operation.
• After recall, activate independent service: If enabled, Independent service will be
activated after recall is complete. The car remains on Independent Service until the
continuous closure switch is opened.
Door Operation Front Determines how the elevator front doors shall operate once the
elevator has arrived at the recall floor (after all car calls have been answered).
• Keep closed: The front doors shall remain closed.
• Keep open: The front doors shall open and remain open.
• Open doors for “xx” sec: The front doors shall open for the time specified, then close.
• Respond to door open button: Specifies that the front doors shall respond to activation of
the front door open button (once the car has arrived at the recall floor). If this option is
selected, the front door open button remains operative at all times. If not selected, the
front door open button will be rendered inoperative when the front doors are closed at the
recall floor. (Note: The door open button will always remain operative when the associated
doors are open).