iView - Controller View
9-96 Manual # 42-02-7223
General Enable destination based dispatching: Enable to activate parameters unique to
destination based dispatching operation.
Door Operation Door operation control during destination dispatching.
Nudge door for special access calls: When checked, the doors close at reduced speed and
torque for special access passengers entering or exiting the elevator.
Door dwell timers
Maximum open time: Maximum time doors may remain open due to dwell times set
below before attempting to close.
Standard call transfer door dwell time: Extends Standard/Standard lobby dwell time
by this amount for each additional passenger entering/exiting at the same floor.
Special access call door dwell time: Sets door dwell time for a special access passenger.
Special access call transfer door dwell time: Extends Special access call door dwell time
by this amount for each additional special access passenger entering / exiting at the
same floor.
•Standard call
Dwell time: Sets base door dwell time at non-lobby floors.
Canceled by - Door close button: Dwell time curtailed if door close button is activated.
Canceled by - Photo eye: Dwell time curtailed if photo eye is activated.
Standard lobby call
Dwell time: Sets base door dwell time at lobby floors.
Canceled by - Door close button: Dwell time curtailed if door close button is activated.
Canceled by - Photo eye: Dwell time curtailed if photo eye is activated.
Anti-nuisance
Without photo eye activation, registered destinations will be cancelled: When enabled,
destinations are cancelled if the photo eye is not interrupted by an entering passenger.
This option helps to avoid registration of nuisance destinations.
Cancel registered destinations if car is empty: When enabled, the car will check the load
weigher value after closing its doors in preparation to leaving the floor. If the load weigher
reports an empty car, all registered destination calls will be cancelled.
Floor settings
Lobby floor 1: / Lobby floor 2: These settings allow you to designate any two floors as
lobby floors. These floors will use the Standard lobby call dwell and transfer door dwell
settings as described under “Door Operation” above.
Disable Main COP car call buttons at DBD floors: When checked, Main COP car call but-
tons are disabled at all DBD source floors. They remain disabled until the car stops at a
floor that is not a source floor.
Disable Aux COP car call buttons at DBD floors: When checked, Aux COP car call buttons
are disabled at all DBD source floors. They remain disabled until the car stops at a floor
that is not a source floor.
•Mode Enabled Main COP
Attendant: When checked, Main COP car call buttons are enabled at all DBD floors
when on Attendant service.
•Mode enabled Aux COP
Attendant: When checked, Aux COP car call buttons are enabled at all DBD floors
when on Attendant service.