The parameters have the following meaning:
Parameter Description Range of values / note
forward-time Keyword for the time after which a port
changes its spanning tree status from
"Blocking" to "Forwarding"
-
seconds Time after which the changeover takes
place
4 ... 30
Default: 15
hello-time Keyword for the time after which the
bridge sends its configuration BPDUs
-
seconds Time after which they are sent 1 ... 2
Default: 2
max-age Keyword for the time after which the in‐
formation of the BPDUs becomes invalid
-
seconds Maximum age of the BPDUs in seconds 6 ... 40
Default: 20
Note
Dependencies when setting the timing
If you specify the time settings for spanning tree, you need to keep to the following two rules:
2 * (forward-time - 1) ≥ max-age
max-age ≥ 2 * (hello-time + 1)
Result
The selected setting for the time is configured.
Further notes
You reset the time settings to the default values with the no spanning-tree forward-
time, no spanning-tree hello-time or no spanning-tree max-age.
If you call the no spanning-tree command without parameters, you disable the spanning
tree function. The configured time settings are retained.
If you call the restart factory command, the system restarts with the factory configuration
settings All rime settings are reset.
You display these settings and other information with the commands that start with show
spanning-tree ....
no spanning-tree (time settings)
Description
With this command in conjunction with the relevant parameter you reset the time settings of
the spanning tree function to the default values.
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
322 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals