If you call the command without parameters, you disable the spanning tree function. The
configured time settings are retained.
If you call the restart factory command, the system restarts with the factory configuration
settings All rime settings are reset.
The default values are as follows:
Parameter Default value
forward-time 15 seconds
hello-time 2 seconds
max-age 20 seconds
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree{forward-time|hello-time|max-age}
The parameters have the following meaning:
Parameter Description
forward-time Time after which a port changes its spanning tree status from "Blocking" to
"Forwarding"
hello-time Time after which the bridge sends its configuration frames (BPDUs)
max-age Time after which the information of the BPDUs becomes invalid
Result
The selected setting for the time is reset to the default value.
Further notes
You configure the time with the spanning-tree command (time settings).
You display these settings and other information with the commands that start with show
spanning-tree ....
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 323

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals