2-67
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
BOOTUP_TEST Messages
BOOTUP_TEST Messages
This section contains the BOOTUP_TEST messages.
BOOTUP_TEST-2
Error Message BOOTUP_TEST-2-EOBC_FAIL: Module [dec] has failed test [chars] on EOBC
due to error [chars]
Explanation The online diagnostic EOBC test has failed.
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-EOBC_SKIP: Module [dec] has failed test [chars] on EOBC
due to error [chars]
Explanation The online diagnostic ManagementPort test has failed.
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-MGMT_PORT_FAIL: Module [dec] has failed test [chars] on
Management Port due to error [chars]
Explanation The online diagnostic ManagementPort test has failed.
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-MGMT_PORT_SKIP: Module [dec] has skipped test [chars]
on Management Port due to error [chars]
Explanation The online diagnostic ManagementPort test is skipped.
Recommended Action No action is required.
BOOTVAR Messages
This section contains the BOOTVAR messages.
BOOTVAR-2
Error Message BOOTVAR-2-ALLOC_MEMORY: Memory allocation failed
Explanation The service failed to allocate memory.
Recommended Action Check if the system is low on memory, if so, reset the switch.