Send document comments to nexus7k-feedback-doc@cisco.com
2-422
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
NPV Messages
Error Message NPV-6-EXT_IF_SELECTED: [chars]
Explanation NPV process has selected an external interface to forward either all frames received on
a server interface or frames received from a specific port WWN.
Recommended Action No action is required.
Error Message NPV-6-FABRIC_PROXY_LOGO_SENT: [chars]
Explanation NPV process sent a LOGO frame to the device as the corresponding external interface
went down.
Recommended Action No action is required.
Error Message NPV-6-FDISC_RCVD: [chars]
Explanation NPV process received an FDISC frame.
Recommended Action No action is required.
Error Message NPV-6-FDISC_SENT: [chars]
Explanation NPV process sent an FDISC frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-FLOGI_RCVD: [chars]
Explanation NPV process received an FLOGI frame.
Recommended Action No action is required.
Error Message NPV-6-INTERNAL_FLOGI_SENT: [chars]
Explanation NPV process sent an internal FLOGI frame to the core switch on an external interface.
Recommended Action No action is required.
Error Message NPV-6-LOGO_RCVD: [chars]
Explanation NPV process received a LOGO frame.
Recommended Action No action is required.
Error Message NPV-6-LOGO_SENT: [chars]
Explanation NPV process sent a LOGO frame.
Recommended Action No action is required.