Send document comments to nexus7k-feedback-doc@cisco.com
2-229
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FSPF Messages
Error Message FSPF-6-DELETE_LSR: LSR deleted for domain [dec]
Explanation The LSR for domain [dec] is deleted from the database.
Recommended Action No action is required.
Error Message FSPF-6-INTF_OPER_DOWN: Down on interface [chars]
Explanation FSPF has become operationally down on interface [chars].
Recommended Action No action is required.
Error Message FSPF-6-INTF_OPER_UP: Up on interface [chars]
Explanation FSPF has become operational on interface [chars].
Recommended Action No action is required.
Error Message FSPF-6-MAX_AGE: LSR [dec] reached Maxage
Explanation The LSR for domain [dec] reached the maximum age and will be deleted from all the
connected switches .
Recommended Action No action is required.
Error Message FSPF-6-ROLLOVER: Rolling over the incarnation number of Local LSR
Explanation The incarnation number of local LSR reached the maximum value and is rolling over.
Recommended Action No action is required.
Error Message FSPF-6-SELF_ORIGINATED: Received local LSR with higher incarnation
number
Explanation A LSR for the local domain was received with incarnation number higher than the one
in database. This situation should only occur initially on a topology change. If this situation persists
the domain assignment of switches may not be unique.
Recommended Action If this message is received continuously check if domain assignment is unique
in the fabric.
Error Message FSPF-6-STATE_CREATED: Internal state created [chars]
Explanation FSPF has created its internal state stateless/stateful [chars].
Recommended Action No action is required.