Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
NPV Messages
Error Message NPV-5-FLEXATTACH_VPWWN_UNASSIGNED: The virtual port WWN has been
unassigned from interface [chars]
Explanation The physical port WWN will be used as port WWN for devices logging in on this
interface.
Recommended Action No action is required.
Error Message NPV-5-FRAME_DISCARDED: [chars]
Explanation NPV process discarded an FC2 frame.
Recommended Action No action is required.
Error Message NPV-5-NPV_LOAD_BALANCE_REINIT: Server ports reinitialized : [chars]
Explanation Server ports are reinitialized to balance the loads on the external interfaces.
Recommended Action No action is required.
Error Message NPV-5-UNEXPECTED_EVENT: [chars]
Explanation NPV process has received an unexpected event in the current state.
Recommended Action No action is required.
NPV-6
Error Message NPV-6-ABTS_SENT: [chars]
Explanation NPV process sent an ABTS frame.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_CORE: [chars]
Explanation NPV process sent an ELS frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_SRV: [chars]
Explanation NPV process sent an ELS frame to the server.
Recommended Action No action is required.