2-228
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FSPF Messages
Error Message FSPF-4-LSR_DROPPED: [chars], Dropping LSR [dec] received on interface
[chars]
Explanation A LSR packet is dropped due to [chars] reason. LSR belonged to domain [dec] and was
received on interface [chars].
Recommended Action Provide the reason given for dropping the LSR and output of 'debug fspf fc pkt'
If the reason is checksum failure investigate possible packet corruption or truncation.
Error Message FSPF-4-LSR_MIN_LS_ARRIVAL: Packet arrived before MIN_LS_ARRIVAL,
Dropping LSR [dec] on interface [chars]
Explanation A LSR packet is dropped as it arrived before MIN_LS_ARRIVAL. LSR belonged to
domain [dec] and was received on interface [chars].
Recommended Action This can occur in transient situation and protocol recovers by retransmitting
the LSR. If the message is seen continuously provide output of 'debug fspf flood ' , 'debug fspf
retrans' and 'debug fspf error '. The message may be seen more often when interoperating with other
vendors.
Error Message FSPF-4-LSU_RX_INIT: Dropping LSU received in state INIT on interface
[chars]
Explanation A LSU packet is dropped as interface [char] is in INIT state when it received the LSU.
Recommended Action This can occur in some transient situationsss. If the problem persists provide
output of 'show fspf VSAN x interface' and 'debug fspf fc pkt ' and 'debug fspf event VSAN x'.
FSPF-5
Error Message FSPF-5-STARTING: Routing daemon started
Explanation FSPF routing daemon has been started.
Recommended Action No action is required.
FSPF-6
Error Message FSPF-6-ADD_LSR: New LSR added for domain [dec]
Explanation A new LSR is added to the database for domain [dec] .
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals