2-494
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-5-PFM_VEM_DETECTED: Host [chars] detected as module [dec]
Explanation A VEM has been detected as a module.
Recommended Action No action is required.
Error Message PLATFORM-5-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its
capacity. possibly due to power cable removal/insertion (Serial number [chars])
Explanation Detected power supply capacity change.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-5-PS_FOUND: Power supply [dec] found (Serial number [chars])
Explanation Power Supply is detected.
Recommended Action No action is required.
Error Message PLATFORM-5-PS_STATUS: PowerSupply [dec] current-status is [chars]
[chars]
Explanation Module in slot [decimal digit] changed status.
Recommended Action No action is required.
Error Message PLATFORM-5-XBAR_DETECT: Xbar [dec] detected (Serial number [chars])
Explanation A new xbar in slot [decimal digit] is detected.
Recommended Action No action is required.
Error Message PLATFORM-5-XBAR_PWRDN: Xbar [dec] powered down (Serial number
[chars])
Explanation The xbar in slot [decimal digit] is powered down.
Recommended Action Enter a 'show module xbar', 'show platform internal all module [decimal digit]'
and 'show module internal all module [decimal digit]' to collect more information if you suspect
module has been powered down due to errors.
Error Message PLATFORM-5-XBAR_PWRUP: Xbar [dec] powered up (Serial number [chars])
Explanation The xbar in slot [decimal digit] is powered up.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals