Send document comments to nexus7k-feedback-doc@cisco.com
2-473
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
PLATFORM Messages
This section contains the PLATFORM messages.
PLATFORM-0
Error Message PLATFORM-0-CHASSIS_CLKSW_MODULE_RESET: Modules reset due to clock
switch
Explanation Chassis clock source has switched and all Vegas line cards will be reset. The system
will automatically continue using redundant clock module.
Recommended Action Refer to the platform document on clock modules.
Error Message PLATFORM-0-CHASSIS_CLKSWITCH: Hardware clock switched to redundant
clock-[dec]
Explanation Clock module on chassis deteted a failure and switched to redundant clock module.
Recommended Action Enter the 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-0-CHASSIS_CLKSWRESET: Switch reset due to clock switch
Explanation Chassis clock source has failed and system will be reset. The system will automatically
start using redundant clock module.
Recommended Action Refer to the platform document on clock modules.
Error Message PLATFORM-0-FAIL_REMOVED: Fan module removed. Fan[dec] has been absent
for [dec] seconds
Explanation Fan module is removed. This could lead to temperature alarms.
Recommended Action Replace the fan module as soon as possible.
Error Message PLATFORM-0-MOD_TEMPMAJALRM: [chars] reported Major temperature alarm.
Sensor=[dec] Temperature=[dec] MajThreshold=[dec]
Explanation Module in slot [decimal digit] exceeded major temperature threshold.
Recommended Action Enter a 'show env temperature' to collect more information.