2-224
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FSCM Messages
FS-DAEMON-2
Error Message FS-DAEMON-2-FSD_ENOSPC_BOOTFLASH: Due to insufficient space, [chars]
image could not be copied to standby bootflash. [chars] image is not present on
standby. Please copy \[chars]\'manually.'
Explanation The system has detected that the image could not be copied due to insufficient space in
the memory.
Recommended Action Remove some unnecessary files on bootflash using
\delete\'commandandcopyimagesfromactivesupervisororfromremotelocation.'
FSCM Messages
This section contains the FSCM messages.
FSCM-2
Error Message FSCM-2-FABRIC_START_CFG_MGR_PROGRAM_EXIT: Fabric Start Cfg Mgr daemon
exiting: [chars]
Explanation FABRIC_START_CFG_MGR daemon is exiting.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
FSPF Messages
This section contains the FSPF messages.
FSPF-2
Error Message FSPF-2-SHUTDOWN: Routing daemon shutting down : [chars]
Explanation FSPF routing daemon is shutting down because of [chars] reason.
Recommended Action An error has occurred. Provide the reason provided and the log files for FSPF.