Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-0-MOD_TEMPSHUTDOWN: [chars] powered down due to major
temperature alarm for Sensor [dec].
Explanation Module in slot [decimal digit] shutdown due to temperature exceeding major threshold.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-0-PFM_EMERGENCY: [chars]
Explanation Platform Emergency.
Recommended Action No action is required.
Error Message PLATFORM-0-SUP_SPROM_ERROR: Unable to read SPROM for Sup in slot [dec]
Explanation The supervisor in slot [decimal digit] was not able to read its SPROM.
Recommended Action No action is required.
Error Message PLATFORM-0-SUP_WRONGSLOTNUM: Supervisor powered up in WRONG
SLOT:[dec] (Serial number [chars])
Explanation The supervisor is comming up in wrong slot [decimal digit].
Recommended Action No action is required.
Error Message PLATFORM-0-SYS_LC_DRIVER_LOAD_FAILED: Failed to load linecard module
drivers
Explanation Failed to load drivers.
Recommended Action Image is possibly corrupt. Try to load a different image.
Error Message PLATFORM-0-SYS_RESET: [chars] System shutdown in [dec] seconds
Explanation The system shutdown in [decimal digit] seconds.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-0-SYS_SHUTDOWN: System shutdown in [dec] seconds due to major
temperature alarm
Explanation The system shutdown in [decimal digit] seconds due to temperature exceeding major
threshold.
Recommended Action Enter a 'show env temperature' to collect more information.